Here is what the EPA's own data shows about tap water in Scranton. According to EPA SDWIS data retrieved June 2026, Scranton is served by 2 active community water systems, together reported to serve about 1,854 people.
As of June 2026, EPA records show 27 violations across the community water system(s) serving Scranton, going back to the earliest EPA record. 17 of these are classified by the EPA as health-based (a contaminant recorded above the limit the EPA tracks); the rest are monitoring or reporting violations. Each is listed by system below, with its status.
What the EPA has on record, by system
Scranton Waterworks
1,542 served · surface water · PWSID AR0000330 - Health-based Coliform (TCR): a health-based violation (a contaminant recorded above the limit the EPA tracks), recorded 9 times between September 2001 and September 2002. The EPA record for these does not include a measured level. All have since returned to compliance, per EPA records.
- Monitoring Revised Total Coliform Rule: a monitoring or reporting violation (a required test or report was late or missed — not a measured exceedance), recorded 3 times in July 2016. All have since returned to compliance, per EPA records.
- Monitoring Lead and Copper Rule: a monitoring or reporting violation (a required test or report was late or missed — not a measured exceedance), recorded once in December 2012. All have since returned to compliance, per EPA records.
- Monitoring Coliform (TCR): a monitoring or reporting violation (a required test or report was late or missed — not a measured exceedance), recorded 3 times in December 2001. All have since returned to compliance, per EPA records.
Morrison Bluff Water System
312 served · surface water · PWSID AR0000709 - Health-based Surface Water Treatment Rule: a health-based violation (a contaminant recorded above the limit the EPA tracks), recorded 6 times between September 2018 and October 2018. The EPA record for these does not include a measured level. EPA records do not show all of these as returned to compliance.
- Health-based Total Haloacetic Acids (HAA5): a health-based violation (a contaminant recorded above the limit the EPA tracks), recorded 2 times in April 2018. The EPA record lists a level of 63 UG/L; the limit (MCL) is 60 UG/L. EPA records do not show all of these as returned to compliance.
- Monitoring Revised Total Coliform Rule: a monitoring or reporting violation (a required test or report was late or missed — not a measured exceedance), recorded 3 times in August 2024. EPA records do not show all of these as returned to compliance.
What this means
A health-based violation means a contaminant was recorded above the limit the EPA tracks for it. A monitoring or reporting violation means a required test or report was late or missed — not that a contaminant was measured above a limit. “Returned to compliance” means the EPA recorded the issue as resolved.
This page summarizes the EPA's own records and does not assess whether your water is safe to drink. For the most current details, you can verify every record directly with the EPA, and contact your water system with questions.
Source: U.S. EPA Envirofacts SDWIS, retrieved June 2026. Records cover the EPA's full reporting history for these systems. Verify at EPA ECHO.